KN-601D Multi-Parameter Patient Monitor uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment. It is used in many kind of wards of hospital, such as ICU, CHD room, neonate room, operation room and so on, in order to supply patient information in time. It is made up of mainframe, display, ECG leads wire, BP cuff, SPO2 sensor and temperature sensor. With 12.1 inch high-resolution display of ECG waveforms, respiratory waveform and blood oxygen pulse pressure volume diagram and the picture is more clearer.
Use for checking patient’s heart rate/pulse rate, NIBP (Systolic pressure, Diastolic pressure, average pressure), IBP(Systolic pressure, Diastolic pressure, average pressure),respiration,ECG,temperature, SPO2 and other parameters.
8 " screen, wide angle of view, TFT color display
diaplay eight waveforms including two-ECG waveforms, one spo2 waveforms and one respiration waveform in one screen.
Real-time display of ECG, SPO2, Breath wave and digital display pulse, respiration, SPO2, temperature, and NIBP etc.
Manual or automatically measure BP for adult or infant
Automatically analyze and store 20 kinds of arrhythmia wave
Trend chart of total date, convenient to diagnosis for doctor
Can connected with inner recorder to print every kind of wave and data automatically or manually
Anti-defibrillation, anti-electrosurgical, can detect the pacemaker
Especially suitable for adult, child and newborn baby
Standard KN communication port, can connect with KN- 601 Color Monitor Center System at any time
AC/DC, rechargeable battery, automatic charge, continual work more than 120 minutes when electric is cut off
Battery |
||
Supply power |
rechargeable lead-acid battery 12V/4.5AH |
|
Use time |
≥120 minute |
|
Lead |
Standard Three leads |
R,L,F, lead mode :Ⅰ,Ⅱ,Ⅲ |
Standard Five leads |
R,L,F,N,C, Lead mode:Ⅰ,Ⅱ,Ⅲ,aVR,aVL,aVF,V; |
|
ECG signal input range |
-8.0mV~+8.0mV |
|
HR sensitivity |
±2% |
|
HR sensitivity |
>200μV |
NIBP |
|||
Measurement Range |
adult |
systolic pressure |
40~270mmHg |
diastolic pressure |
10~215mmHg |
||
mean pressure |
20~235mmHg |
||
pediatrics |
systolic pressure |
40~200mmHg |
|
systolic pressure |
10~150mmHg |
||
mean pressure |
20~165mmHg |
||
neonate |
systolic pressure |
40~135mmHg |
|
systolic pressure |
10~100mmHg |
||
mean pressure |
20~110mmHg |
SPO2 |
|
SpO2 measurement range precision |
0~100% ±2%(70~100% ) |
PR measurement range precision |
20~300 bpm ±2% |
RESP |
|
Measurement range |
adult 7~120 bpm |
Precision |
±2bpm |
TEMP |
|
Measurement range |
0°C~50.0°C |
Precision |
±0.1°C |